1.
Cancers (Basel) ; 15(9)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37173938

RESUMO

Microbeam radiotherapy (MRT), a high dose rate radiotherapy technique using spatial dose fractionation at the micrometre range, has shown a high therapeutic efficacy in vivo in different tumour entities, including lung cancer. We have conducted a toxicity study for the spinal cord as organ of risk during irradiation of a target in the thoracic cavity. In young adult rats, the lower thoracic spinal cord was irradiated over a length of 2 cm with an array of quasi-parallel microbeams of 50 µm width, spaced at a centre-to-centre distance of 400 µm, with MRT peak doses up to 800 Gy. No acute or subacute adverse effects were observed within the first week after irradiation up to MRT peak doses of 400 Gy. No significant differences were seen between irradiated animals and non-irradiated controls in motor function and sensitivity, open field test and somatosensory evoked potentials (SSEP). After irradiation with MRT peak doses of 450-800 Gy, dose-dependent neurologic signs occurred. Provided that long-term studies do not reveal significant morbidity due to late toxicity, an MRT dose of 400 Gy can be considered safe for the spinal cord in the tested beam geometry and field size.

2.
J Synchrotron Radiat ; 29(Pt 4): 1027-1032, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35787570

RESUMO

Microbeam radiotherapy could help to cure malignant tumours which are currently still considered therapy-resistant. With an irradiation target in the thoracic cavity, the heart would be one of the most important organs at risk. To assess the acute adverse effects of microbeam irradiation in the heart, a powerful ex vivo tool was created by combining the Langendorff model of the isolated beating mammalian heart with X-Tream dosimetry. In a first pilot experiment conducted at the Biomedical and Imaging Beamline of the Australian Synchrotron, the system was tested at a microbeam peak dose approximately ten times higher than the anticipated future microbeam irradiation treatment doses. The entire heart was irradiated with a dose of 4000 Gy at a dose rate of >6000 Gy s-1, using an array of 50 µm-wide microbeams spaced at a centre-to-centre distance of 400 µm. Although temporary arrhythmias were seen, they reverted spontaneously to a stable rhythm and no cardiac arrest occurred. This amazing preservation of cardiac function is promising for future therapeutic approaches.


Assuntos
Radiometria , Síncrotrons , Animais , Austrália , Mamíferos , Radiometria/métodos
3.
Int J Radiat Oncol Biol Phys ; 114(1): 143-152, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35533907

RESUMO

PURPOSE: Microbeam radiation therapy (MRT) has shown several advantages compared with conventional broad-beam radiation therapy in small animal models, including a better preservation of normal tissue function and improved drug delivery based on a rapidly increased vascular permeability in the target region. Normal tissue tolerance is the limiting factor in clinical radiation therapy. Knowledge of the normal tissue tolerance of organs at risk is therefore a prerequisite in evaluating any new radiation therapy approach. With an irradiation target in the thoracic cavity, the heart would be the most important organ at risk. METHODS AND MATERIALS: We used the ex vivo beating rodent heart in the Langendorff perfusion system at the synchrotron to administer microbeam irradiation (MBI) with a peak dose of 40 or 400 Gy. By continuously recording the electrocardiogram, the left ventricular pressure, and the aortic pressure before, during and after MBI, we were able to assess acute and subacute effects of MBI on electrophysiological and mechanical cardiac function. In addition, we analyzed histologic and ultrastructural sequelae caused by MBI. RESULTS: There were no significant changes in heart rate, heart rate variability, systolic increase of left ventricular pressure or aortic pressure. Moreover, the changes of heart rate, left ventricular pressure and aortic pressure by adding 10-5 mol/L norepinephrine to the perfusate, were also not significant between MBI and sham experiments. However, the rate-pressure product as a surrogate marker for maximum workload after MBI was significantly lower compared with sham-irradiated controls. On the structural level, no severe membranous, sarcomeric, mitochondrial or nuclear changes caused by MBI were detected by desmin immunohistochemistry and electron microscopy. CONCLUSIONS: With respect to acute and subacute toxicity, an MBI peak dose up to 400 Gy did not result in severe changes in cardiac electrophysiology or mechanics.


Assuntos
Roedores , Síncrotrons , Animais , Coração , Imuno-Histoquímica , Modelos Animais
4.
Int J Radiat Oncol Biol Phys ; 111(5): 1276-1288, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34364976

RESUMO

PURPOSE: In the past 3 decades, synchrotron microbeam radiation therapy (S-MRT) has been shown to achieve both good tumor control and normal tissue sparing in a range of preclinical animal models. However, the use of S-MRT for the treatment of lung tumors has not yet been investigated. This study is the first to evaluate the therapeutic efficacy of S-MRT for the treatment of lung carcinoma, using a new syngeneic and orthotopic mouse model. METHODS AND MATERIALS: Lewis Lung carcinoma-bearing mice were irradiated with 2 cross-fired arrays of S-MRT or synchrotron broad-beam (S-BB) radiation therapy. S-MRT consisted of 17 microbeams with a width of 50 µm and center-to-center spacing of 400 µm. Each microbeam delivered a peak entrance dose of 400 Gy whereas S-BB delivered a homogeneous entrance dose of 5.16 Gy (corresponding to the S-MRT valley dose). RESULTS: Both treatments prolonged the survival of mice relative to the untreated controls. However, mice in the S-MRT group developed severe pulmonary edema around the irradiated carcinomas and did not have improved survival relative to the S-BB group. Subsequent postmortem examination of tumor size revealed that the mice in the S-MRT group had notably smaller tumor volume compared with the S-BB group, despite the presence of edema. Mice that were sham-implanted did not display any decline in health after S-MRT, experiencing only mild and transient edema between 4 days and 3 months postirradiation which disappeared after 4 months. Finally, a parallel study investigating the lungs of healthy mice showed the complete absence of radiation-induced pulmonary fibrosis 6 months after S-MRT. CONCLUSIONS: S-MRT is a promising tool for the treatment of lung carcinoma, reducing tumor size compared with mice treated with S-BB and sparing healthy lungs from pulmonary fibrosis. Future experiments should focus on optimizing S-MRT parameters to minimize pulmonary edema and maximize the therapeutic ratio.


Assuntos
Neoplasias Pulmonares , Edema Pulmonar , Fibrose Pulmonar , Animais , Pulmão , Neoplasias Pulmonares/radioterapia , Camundongos , Síncrotrons
5.
J Synchrotron Radiat ; 27(Pt 1): 164-175, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31868749

RESUMO

Small-animal physiology studies are typically complicated, but the level of complexity is greatly increased when performing live-animal X-ray imaging studies at synchrotron and compact light sources. This group has extensive experience in these types of studies at the SPring-8 and Australian synchrotrons, as well as the Munich Compact Light Source. These experimental settings produce unique challenges. Experiments are always performed in an isolated radiation enclosure not specifically designed for live-animal imaging. This requires equipment adapted to physiological monitoring and test-substance delivery, as well as shuttering to reduce the radiation dose. Experiment designs must also take into account the fixed location, size and orientation of the X-ray beam. This article describes the techniques developed to overcome the challenges involved in respiratory X-ray imaging of live animals at synchrotrons, now enabling increasingly sophisticated imaging protocols.


Assuntos
Radiografia/métodos , Mecânica Respiratória , Sistema Respiratório/diagnóstico por imagem , Síncrotrons , Aerossóis , Anestesia Geral/métodos , Animais , Autopsia/métodos , Tamanho Corporal , Temperatura Corporal , Umidificadores , Camundongos , Pentobarbital , Doses de Radiação , Ratos , Respiração Artificial/métodos , Suínos
6.
J Synchrotron Radiat ; 26(Pt 1): 175-183, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30655483

RESUMO

The Australian Synchrotron Imaging and Medical Beamline (IMBL) was designed to be the world's widest synchrotron X-ray beam, partly to enable clinical imaging and therapeutic applications for humans, as well as for imaging large-animal models. Our group is currently interested in imaging the airways of newly developed cystic fibrosis (CF) animal models that display human-like lung disease, such as the CF pig. One key outcome measure for assessing the effectiveness of CF airway therapies is the ability of the lung to clear inhaled particulates by mucociliary transit (MCT). This study extends the ex vivo sheep and pig tracheal-tissue studies previously performed by the authors at the IMBL. In the present study, attempts were made to determine whether the design of the IMBL is suitable for imaging tracheal MCT in live pigs. The movement of 200 µm-diameter high-refractive-index (HRI) glass-bead marker particles deposited onto the tracheal airway surface of eight live piglets was tracked and quantified and the MCT response to aerosol delivery was examined. A high-resolution computed tomographic (CT) whole-animal post-mortem scan of one pig was also performed to verify the large sample CT capabilities of the IMBL. MCT tracking particles were visible in all animals, and the automated MCT tracking algorithms used were able to identify and track many particles, but accuracy was reduced when particles moved faster than ∼6 mm min-1 (50 pixels between exposures), or when the particles touched or overlapped. Renderings were successfully made from the CT data set. Technical issues prevented use of reliable shuttering and hence radiation doses were variable. Since dose must be carefully controlled in future studies, estimates of the minimum achievable radiation doses using this experiment design are shown. In summary, this study demonstrated the suitability of the IMBL for large-animal tracheal MCT imaging, and for whole-animal CT.


Assuntos
Aerossóis/administração & dosagem , Depuração Mucociliar/fisiologia , Tomografia Computadorizada por Raios X/métodos , Traqueia/diagnóstico por imagem , Imagem Corporal Total , Algoritmos , Animais , Austrália , Fibrose Cística/tratamento farmacológico , Fibrose Cística/fisiopatologia , Modelos Animais de Doenças , Técnicas In Vitro , Tamanho da Partícula , Projetos Piloto , Doses de Radiação , Suínos , Síncrotrons
7.
Strategies Trauma Limb Reconstr ; 13(3): 137-149, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30220005

RESUMO

External fixation is a common tool in the treatment of complex fractures, correction of limb deformity, and salvage arthrodesis. These devices typically incorporate radio-opaque metal rods/struts connected at varying distances and orientations between rings. Whilst the predominant imaging modality is plain film radiology, computed tomography (CT) may be performed in order for the surgeon to make a more confident clinical decision (e.g. timing of frame removal, assessment of degree of arthrodesis). We used a fractured sheep leg to systematically assess CT imaging performance with a Discovery CT750 HD CT scanner (GE Healthcare) to show how rod coupling in both traditional Ilizarov and hexapod frames distorts images. We also investigated the role of dual-energy CT (DECT) and metal artefact reduction software (MARS) on the visualisation of the fractured leg. Whilst mechanical reasons predominantly dictate the rod/strut configurations when building a circular frame, rod coupling in CT can be minimised. Firstly, ideally, all or all but one rod can be removed during imaging resulting in no rod coupling. If this is not possible, strategies for configuring the rods to minimise the effect of the rod coupling on the region of interest are demonstrated, e.g., in the case of a four-rod construct, switching the two anterior rods to a more central single one will achieve this goal without particularly jeopardising mechanical strength for a short period. It is also shown that the addition of DECT and MARS results in a reduction of artefacts, but also affects tissue and bone differentiation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...